Thermistor Heat Detector

Conventional thermistor indicating heat detectors. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow). NZS 4512-approved

Thermistor Heat Det. Weatherproof

Conventional thermistor indicating heat detectors. Weatherproof. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512-approved

Thermistor Heat Detector w Remote

Conv. thermistor indicating heat detectors Terminals for remote indicator Alarm threshold: 57 °C (blue), 77 °C (yellow) NZS 4512-approved

Thermistor Heat Det. Alk. Resistant

Conv. thermistor indicating heat detectors. Alkaline wash resistant. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow) NZS 4512-approved

THD for Freezers

Conventional thermistor indicating heat detector. Fixed alarm threshold: 57 °C NZS 4512 type (blue) Suitable for freezers and cool stores

2151BPI Detector

Conventional photoelectric smoke detector. Available in white and ivory

2351E Detector

Conventional photoelectric smoke detector

2351TEM Detector

Conventional multi-criteria detector. Photoelectric smoke, configurable as low, medium, or high sensitivity. 58 °C rate of rise heat sensor

4351E Detector

Conventional heat detector with 78 °C fixed alarm temperature threshold

5351E Detector

Conventional rate of rise heat detector with 58 °C fixed alarm temperature threshold

5351TE Detector

Conventional heat detector with 58 °C fixed alarm temperature threshold

IHD*-V

Conventional indicating heat detectors. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow). NZS 4512-compliant

IHD*EAR-V

Conv. indicating heat detectors. Alkaline wash resistant. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512-compliant

IHD*R-V

Conv. indicating heat detectors. Terminals for remote indicator. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512-compliant

HD*-V

Conv. non-indicating heat detectors, with or without encapsulation. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512:1997-compl

2W-B Detector

2-wire conventional photoelectric smoke detector

2WTA-B Detector

Multi-criteria detector, 2-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed alarm threshold and alarm sounder

4W-B Detector

4-wire conventional photoelectric smoke detector

IHD*E-V

Conventional indicating heat detectors. Encapsulated. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow). NZS 4512-compliant

IHD Kit

Conventional bi-metallic indicating heat detectors with remote sensor. Fixed threshold: 57 °C (blue) or 125 °C (black). NZS 4512-compliant

4WT-B Detector

Multi-criteria detector, 4-wire, with photoelectric smoke sensor and heat sensor with 58 °C fixed alarm threshold

4WTAR-B Detector

Multi-criteria detector, 4-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed alarm threshold, sounder, and relay

4WTR-B Detector

Multi-criteria detector, 4-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed alarm threshold and relay

2012/24AUSI Detector

Photoelectric Smoke Alarm 4-wire, 12 V / 24 V with 9 V battery AS 3786:2014

PC614 Detector

Conventional carbon monoxide (CO) and rate-of-temperature-rise heat detector. Suitable for detecting slow-smoldering and fast-flaming fires.

DETREM Remote LED Indicator

Remote LED indicator

Sensitivity Reader

This tool is to measure the sensitivity of System Sensor model 2151BPI conventional photo-electronic smoke detectors.